Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell

Product Details
Customization: Available
Application Fields: New Energy
Certification: ISO, CE
Still deciding? Get samples of US$ 20000/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
3000 square meters
  • Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
  • Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
  • Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
  • Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
  • Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
  • Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Our Advantages
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
VMP-0.5-300/16
Condition
New
Noise Level
Low
Parts
Gas Tank
Purpose
Gas Manufacturing
Capacity
0.5-300nm3/H
Cell Rate
4lpm
Working Pressure
up to 3.2MPa
H2 Purity
99.9999% (After Purification)
Working Temperature
40-60 Deg.C
Life Time
80000+H
Usage
Hydrogen, Oxygen
Machine Size
Medium
Transport Package
Wooden Case for Exportation
Specification
Customized
Trademark
OEM/ODM/VMA
Origin
China
HS Code
8543300090
Production Capacity
2000units/Year

Product Description

Product Description

PEM Water Electrolysis Electrolyzer Stack
Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell   Hydrogen Output: 600-3000ml/min

Model

VMB-600ML

VMB-900ML

VMB-1200ML

VMC-1500ML

VMC-2000ML

VMC-3000ML

H2 flow ml/min

600

900

1200

1500

2000

3000

Current DCA

45

45

45

73

73

73

Voltage DCV

3.6-5

5.4-7.5

7.2-10

5.4-7.5

7.2-10

10-15

Power consumption kW·h/m3

≤4.50

≤4.50

≤4.50

≤4.50

≤4.50

≤4.50

Cell Nos.

2

3

4

3

4

6

Electrode Efficiency

80%

80%

80%

80%

80%

80%

Working Temp. ºC

40-60

40-60

40-60

40-60

40-60

40-60

Water Quality ≥MΩ·cm²

15

15

15

15

15

15

Pressure (H2)

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

Pressure (H2O)

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

Dimensions mm

96*86*36

96*86*40

96*86*42

124*124*45

124*124*48

124*124*54

Hydrogen Output: 0.5-5Nm3/h

Model

VMD-0.5M

VMD-1M

VMD-2M

VME-3M

VME-4M

VME-5M

H2 flow Nm3/h

0.5

1

2

3

4

5

Current DCA

147

147

147

765

765

765

Voltage DCV

16-23

30-43

60-86

18-25

23-33

28-40

Power consumption kW·h/m3

≤4.50

≤4.50

≤4.50

≤4.50

≤4.50

≤4.50

Cell Nos.

9

17

34

10

13

16

Electrode Efficiency

80%

80%

80%

80%

80%

80%

Working Temp. ºC

40-60

40-60

40-60

40-60

40-60

40-60

Water Quality ≥MΩ·cm²

15

15

15

15

15

15

Pressure (H2)

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

Pressure (H2O)

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

Dimensions mm

254*141*81

254*141*106

254*141*155

509*284*120

509*284*129

509*284*172

Hydrogen Output: 10-200Nm3/h

Model

VME-10M

VMF-15M

VMF-20M

VMG-50M

VMG-100M

VMH-200M

H2 flow Nm3/h

10

15

20

50

100

200

Current DCA

765

765

1575

4725

4725

4725

Voltage DCV

57-80

84-118

57-80

68-95

90-125

180-250

Power consumption kW·h/m3

≤4.50

≤4.50

≤4.50

≤4.50

≤4.50

≤4.50

Cell Nos.

32

47

32

25

50

100

Electrode Efficiency

80%

80%

80%

80%

80%

80%

Working Temp. ºC

40-60

40-60

40-60

40-60

40-60

40-60

Water Quality ≥MΩ·cm²

15

15

15

15

15

15

Pressure (H2)

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

≤3.2MPa

Pressure (H2O)

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

≤0.5MPa

Dimensions mm

509*284*232

509*284*292

705*396*235

960*530*230

960*530*310

960*530*520

Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel CellPem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel CellPem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel CellAlkaline Water Electrolysis Hydrogen Electrolyzer Stack

H2 Output Capacity 

0.5-1000Nm3/h

O2 Output Capacity

0.25-500Nm3/h

H2 Purity (Before Purification)

99.8%+/-0.2

H2 Purity (After Purificaiton)

99.9999%

O2 Purity (Before Purificaiton)

98.5%+/-0.5

H2 Dew Point

<=-65ºC

Working Load

30-100%

Working Pressure

 up to 3.2Mpa

DC Power Consumption

<=4.5Kw.h/Nm3 H2

Working Temperature

 85+/-5ºC


Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel CellUtilites and Related Equipment

Water 
Alkaline Hydrogen Generator will consume some DM water, normaly 1liter of DM water per Nm3 of H2.
Because the electrolysis and H2 purification process will produce some heat, so it will also need cooling water circulation to cool the gas and system.


Power  
The electrolyzer stack use DC power, and normally the power supply should be 7time of the expected capacity of the Hydrogen Plant.

Instrument air   
For driving instruments

Our system contains Hydrogen Generator, power supply system, PLC control system; and we can also provied auxiliary equipments such as water purifier, water chiller, air compressor, ext.
 

Company Profile


Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell
Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel CellPEM Hydrogen Generator
Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell

Our Advantages

Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell

Key Benefits

Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell

Packaging & Shipping

 

Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel CellWaranty Period

12 months from the date of successful comissioning of the equipment or 18 months from the date of equipment delivery, whichever comes first.

Testing and Process
Pem Water Electrolysis Green Hydrogen Electrolyzer Generator for Pem Fuel Cell

First Step to Have One More Choice

 

VMA is one of very few companies that offer both the expertise and the technologies to help sectors that are difficult to reduce carbon emissions and enterprises who want to embark on green energy futures. Our green Hydrogen solutions will power a sustainable future.

Tell us about your project plans or just say hello. Whether you've got a big idea or need some inspiration with a green hydrogen plant construction project, we are here to create perfect green hydrogen plants. From concept to creation, let us inspire you.

                      Towards 100% New Energy, Let's Connect!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier